Find answers to hard drive failure on hp smart array p410i from the expert community at experts exchange. Hp dl360p gen8 p420i controller ixsystems community. Hp smart array p410256mb controller storage controller raid sata150 sas low profile 300 mbps raid 0, 1, 5, 10, 50 pci express x8 smart array p410256mb pcie2 int only manufacturer part number 462862b21. This is for the hardware guys, i have installed an ssd drive to a p410i raid controller and the io is awful does not gets more than 61mbs where this should be around 500mbs, i have changed a lot of settings on the controller, disable cache and nothing makes any difference. Hp smart array p410i controller raid configuration. Installing and configuring sas hardware raid on hp workstations. Hard drive failure on hp smart array p410i solutions. Product bulletin, research or buy hp printers, desktops, laptops, servers, storage, enterprise solutions and more at the official hewlettpackard website. Software cd or web software cd or web preinstalled in rom of hp smart array controllers when the utility can be used. Hp proliant smart array controllers, hp proliant integrated smart array controllers, and hp proliant storageworks raid array controllers. Hp proliant integrated smart array controllers, and hp proliant storageworks raid array controllers. Hp smart array p410i1g with fbwc storage controller raid sata 1. Hardwareassisted sas raid uses the lsi megaraid driver already present in the linux.
Aug 02, 2015 hp dl360 g7 p410i controller troubleshooting up vote1down vote favorite. Raid 10 uses effectively no controller overhead, so the controller is idle. Hp 451792001 512mb batery backed write cache bbwc module ddr2533mhz, 72bit wide for hp smart array p410i and p700m controllers hp hp smart array p410256mb controller. Smart array p212, p410, p410i, p411, p711m, p712m, and p812. Hp smart array p410 raid controller stops working after. My unit has the 256mb cache on it and i would love to get raid 6 enabled. The product literature says you can but im looking for realworld. I cannot configure the raid on my p410i, and the only reason i can imagine. I have a hp elitebook 8570w that was shipped with windows 7. Hp smart array controllers for hp proliant servers user guide. Hp p410i raid controller terrible sequential write. It provides enterpriseclass storage performance, and increased scalability and data protection to hpe synergy compute modules. Configuring arrays on hp smart array controllers reference guide part number 433572006 june 2010 sixth edition.
You cant just toss some consumer drives into the server and expect them to work. If i remember correctly the hp sas expander card is only officially supported with the p410 and p410i raid controllers though, not the p411 you mentioned. I installed an hp p410 raid controller in my hp n40l proliant microserver. I have attached a single 2tb sata samsung hard drive and created a raid 0 array with the single drive. To configure an array on an hp smart array controller, three utilities are available.
The drives have not failed, but they definitely are not meant to be used with that controller. You can use the array configuration utility for several tasks such as configuring. You are in the range where the controller isnt even working to do anything. Do you users of hp p410i raid controllers as found in the dl380g6 know if one can mix and match sata arrays with sas ones. Also, any suggestions on how to determine if the p410i is a bottleneck would be helpful. I entered configuration utility for the raid controller hp smart array p410i and removed all logical drives, as there is no need for a hardware raid if youre going to use zfs. If you do not press any key, you will be given a chance to run the option rom. Hpe ssa replaces the existing hp array configuration utility, or acu, with an. Hp smart array p410i controller hp proliant dl 360 365 raid hp smart array p410i. At any rate you should be able to manage the array with the software within windows. Open the firmware storage controller and download the supplemental update. Hp protectsguards against that by restricting thirdparty drive use in their servers.
You arent in the ballpark of the controller being the bottleneck. Hdds will be visible to operating system only as logical devices after they are configured in controller. If the raid controller presents one drive to the os, that is what the os will see. Hp smart array p420i controller storage controller raid sata 6gbs sas 6gbs pcie 3. Configuring arrays on hp smart array controllers reference. Install firmware for the hp p410i storage controller in. Software raid todays operating systems offer basic support for raid disks called software raid to create and manage logical drives that do not contain the os. Joule has an hp p410 with 1g flash back cache smart array controller. The smart array controller moves the data from the cache to the drams, verifies that the data is correct, and then transfers it to the disk drives. Is there supposed to be a license number that needs to be added to make the card work. When the controller displays press to run the option rom configuration for arrays utility, press f8.
As expected hp smart array p410i is not supporting raid6 and it is not transparent to operating system i. In 16bay systems there is usually a p410 along with a p410i controller. Installing a license key with array configuration utility acu. Although the only difference i can see is that the p411 has its two sas connectors external and it supports a maximum of 100 drives to the p410s maximum support for 24 drives. The low profile, half height card has 8 ports and utilizes ddr2800 memory. Theres no raid setup utility when the system boots. The overall impression regarding building storage system on hp proliant dl380 g7 is miserable. This driver provides support for the hp smart array b110i sata raid controller on microsoft windows server 2012 and microsoft windows server 2012 r2. Hp proliant bl460c g7 64bit blade server with 2xsixcore x5675 xeon 3. Six 6 available pciexpress gen 2 expansion slots standard with optional pcixpcix express or x16 risers.
Hp smart array controllers for hp proliant servers user guide part number 469988005 february 2010 fifth edition. The hp array configuration utility is a webbased application that helps you configure hp. Software raid is just one option out of many on freenas, just as zfs is only an option there. Hp p410 raid controller and ssd oletho oct 15, 20 8.
Hardwareassisted raid is a step up from software raid, but is not considered true hardware raid. Installing and configuring sas hardware raid on hp. The controller is running well in a parallel installation of windows server 2016 on the same hw and in the old w10 1703. Hp smart array p410 controller hewlett packard enterprise. The lsi 3041e is a 4port satasas raid controller providing sas support for the hp xw4000 and. But i see no way of getting notification of a drive failure other than having to manually open the hp array configuration utility software yourself. Hp p410i raid controller does not like ssd drives lowendtalk. Hi all, i cannot find the right driver for the raid controller. Hp proliant bl460c g7 64bit blade server with 2xsixcore. Slow drive speeds with hp smart array p410i servethehome. I have 4 drives to setup as a raid 5 configuration but cannot figure out how to do this. Hp proliant smart array embedded sata raid controller driver. I have ran some disk benchmarks on this drives and i get mbps read and only 10mbps write speeds.
Discussion in servers and enterprise solutions started by lixxus, nov 16, 2015. Install firmware for the hp p410i storage controller using. I have just installed windows 10 on a seperate partition of my hard drive so i have both operating systems currently. Linux hp smart array raid controller sumguys ramblings. I checked the bios and it shows the raid controller as the primary boot device.
Smart array controllers and smart host bus adapters hpe. Hewlett packard enterprise hpe smart array p420i raid. Im working on a z840 workstation with a windows server 2016 6544588. The option rom messages will go through each raid controller installed on the system. I have a an hp dl380 g7 server with a hp smart array p410i raid card. Hp smart array p420i controller storage controller raid. Hp smart array p410i controller raid configuration youtube. I wanted to keep an eye on the hdds, so i needed to install a utility that can monitor and interact with the raid controller.
The hp array configuration utility is a webbased application that helps you configure hp proliant smart2 array controllers, hp proliant smart array controllers, hp proliant integrated smart array controllers, and hp proliant storageworks raid array controllers. However as its laid out, best of luck getting up and running quickly if you follow that page. I have a question about hp p410 raid smart array controller card. I was trying to install nas4free freebsd on a hp proliant dl380g7. Hp p410i raid controller, mix and match sata and sas. Hp ml350 g6 smart array p410i controller raid 5 1 array 1 logical drive 6 tb drive configuration. Hardware installed remotely and it is difficult to reach noc every week to check drives status. Hp smart array p410 raid controller management server. The hpe smart array p420i controller is a low profile, 6 gbs, pcie 3. We purchased an hp ml350 g6 server with a p410i raid controller. You can use the array configuration utility for several. Hp smart array p410i controller raid configuration it blog ixnfo. Hp 462919001 smart array p410 sas controller newegg.
The server boots and i can start up linux mint from usb, but when i tried to install it to a hard drive, machine reported no drives found. The low profile, halfheight card has 8 ports and utilizes ddr2800 memory. The official hp software page for the information below is here. So i just recently acquired an hp dl360 g7 with an integrated p410i raid controller. Some software requires a valid warranty, current hewlett packard. As you have a hardware raid controller youd be mad to just use it for jbod, only to then raid the disks in software. Hp p410 raid smart array controller card anandtech. The hp smart array p410i raid controller is not compatible with every ssd.